Tuesday, July 28, 2015

Firmware Updates for Dranetz HDPQ & Dran-View 7

Dranetz is pleased to announce the release of V1.2.8 for the Dranetz HDPQ family and V7.1.01 for Dran-View 7. Both are available for download on our web site at:
www.dranetz.com/technical-support-request/612-2/
On this page you will find a link to download these new versions, as well as installation instructions. 
Dranetz HDPQ V1.2.8 corrects several known bugs and anomalies. We always recommend that you upgrade to the latest version of firmware in order to take advantage of these enhancements. Note that this firmware upgrade applies to all Dranetz HDPQ instruments – Visa, Guide, Xplorer and Xplorer 400, and the same firmware update files can be installed on any model instrument.
In addition to being posted to our web site, Dran-View V7.1.01 has also been posted to the Dran-View update server, so it should automatically update if that feature is enabled in your copy of Dran-View. You can also upgrade immediately from within Dran-View by clicking the “Check for Updates Now” button in the Automatic Updates area of the Dran-View Options menu. 
IMPORTANT: It is very important to note that when upgrading your Dranetz HDPQ to V1.2.8 (or newer), Dran-View 7 software must also be updated to V7.1.01 (or newer). V1.2.8 includes a new database format that greatly improves the compression in order to reduce the size of the database, so Dran-View 7 must also be upgraded to be compatible with this new database format. Dran-View V7.1.01 is downward compatible with all Dranetz HDPQ versions prior to V1.2.8.
To Contact Dranetz: 

Friday, May 8, 2015

Dranetz HDPQ Firmware Version Identification


INTRODUCTION
The Dranetz HDPQ family of Power Quality, Demand and Energy instruments represent the latest in Instrumentation technology from Dranetz. Like most modern instruments, each Dranetz HDPQ instrument incudes multiple computer processors that perform various tasks. When Dranetz provides a firmware update to improve the instrument, updates to some or all of the computer processors may be included.


This TechTip shows you where to find the processor firmware version(s) that are installed in your Dranetz HDPQ instrument and how to know if a newer version is available.

FINDING THE FIRMWARE VERSIONS

The firmware version of each processor can be found by pressing the Instrument Status icon at the top of the screen – it’s the icon that looks like the instrument and is circled below.








The Instrument Status screen (see below) shows general information about the instrument and its health. The instrument firmware versions are located in the third line from the top.


















There are 4 firmware versions shown, each indicated by a 2 letter abbreviation. They are listed from left to right in the order shown below:

MP: Measure Process 
OS: Operating System 
HP: Host Processor
BP: Battery Processor

The right side shows each processor version in the same order.

Even though there are 4 versions of firmware shown, Dranetz always uses the version of the HP (host processor) when referencing the instruments firmware version. In other words, Dranetz may announce that V1.1.2 has been released. V1.1.2 is the version number of the overall release and also that of the HP. The HP version shown in the instrument is the firmware version of the overall instruments.

It’s important to note that all 4 firmware files are included in every release and they are all automatically installed from the same firmware installation file.

WHERE DO I FIND THE LATEST DRANETZ HDPQ FIRMWARE?
The current version of Dranetz HDPQ firmware is available on our web site at the following link:
www.dranetz.com/technical-support-request/612-2/

Installation is quick and easy, and instructions are also provided. The upgrade process simply involves downloading the new firmware release to a USB memory drive, inserting the USB drive into the USB port of the instrument, and selecting the firmware upgrade option on the LCD screen. There are actually a few more steps, , so please consult the installation procedure posted on our web site or the instruments Users Guide for more information.

Please also note that each firmware release and the downloaded firmware applies to all Dranetz HDPQ instrument models (Visa, Guide, Xplorer, Xplorer-400).